Description
Product information "HI88713 Benchtop Turbidity, ISO 7027"
Graphic display, backlit LCD
Two, three, four or five point calibration
GLP features
Log up to 200 records
Contextual help and tutorial mode
USB PC connectivity
The HI 88713 turbidity bench meter meets and exceeds the requirements of the ISO 7027 standard.
HI 88713 is based on an optical system which guarantees accurate results, long term stability and minimizes stray light and color interferences. It also compensates for variations in intensity of the LED, limiting the need for frequent calibration.
Depending on the measured sample and needed accuracy, normal, continuous or signal averaging measurement can be selected.
A two, three, four or five-point calibration can be performed using the supplied standards. Calibration points can be modified when user prepared standards are used.
The HI 88713 turbidity bench meter has complete GLP (Good Laboratory Practice) functions that allow traceability of the calibration conditions.
The HI 88713 turbidity bench meter has a user-friendly interface with an easy to understand, graphic LCD. Comprehensive contextual help is available at a simple key press. Furthermore, a tutorial mode of operation guides the user step by step through the analysis process.
Up to 200 measurements can be stored in internal memory. Data can be transferred to a PC via optional HI 920013 USB cable and HI 92000 Windows® compatible software.
Order Information: HI 88713-02 (230V) is supplied with sample cuvettes and caps (6), calibration cuvettes, silicone oil, tissue for wiping cuvettes, power adapter and instruction manual.
Specification :
Range FNU Mode 0.00 to 9.99; 10.0 to 99.9; 100 to 1000 FNU
FAU Mode 10.0 to 99.9; 100 to 4000 FAU
NTU Ratio Mode 0.00 to 9.99; 10.0 to 99.9; 100 to 4000 NTU 0.00 to 9.99; 10.0 to 99.9; 100 to 980 EBC
NTU Non-Ratio Mode 0.00 to 9.99; 10.0 to 99.9; 100 to 1000 NTU 0.00 to 9.99; 10.0 to 99.9; 100 to 245 EBC
Resolution FNU Mode 0.01; 0.1; 1 FNU
FAU Mode 0.1; 1 FAU
NTU Ratio Mode 0.01; 0.1; 1 NTU / 0.01; 0.1; 1 EBC
NTU Non-Ratio Mode 0.01; 0.1; 1 NTU / 0.01; 0.1; 1 EBC
Accuracy @25°C FNU Mode ±2% of reading plus stray light
FAU Mode ±10% of reading
NTU Ratio Mode ±2% of reading plus stray light / ±5% of reading above 1000 NTU
NTU Non-Ratio Mode ±2% of reading plus stray light
Range Selection automatic
Repeatability ±1% of reading or stray light, whichever is greater
Stray Light < 0.1 NTU (0.05 EBC)
Light Detector silicon photocell
Light Source IR LED
Method ISO 7027 Method
Measuring Mode normal, average, continuous.
Turbidity Standards <0.1, 15, 100, 750 FNU and 2000 NTU
Calibration two, three, four or five-point calibration
Log Memory 200 records
PC Connectivity USB
Environment 0°C (32°F) to 50°C (122°F); max 95% RH non-condensing
Power Supply 12 Vdc power input
Dimensions / Weight 230 x 200 x 145 mm (9 x 7.9 x 5.7”) / 2.5 Kg (88 oz.)
Product information "HI88713 Benchtop Turbidity, ISO 7027"
Graphic display, backlit LCD
Two, three, four or five point calibration
GLP features
Log up to 200 records
Contextual help and tutorial mode
USB PC connectivity
The HI 88713 turbidity bench meter meets and exceeds the requirements of the ISO 7027 standard.
HI 88713 is based on an optical system which guarantees accurate results, long term stability and minimizes stray light and color interferences. It also compensates for variations in intensity of the LED, limiting the need for frequent calibration.
Depending on the measured sample and needed accuracy, normal, continuous or signal averaging measurement can be selected.
A two, three, four or five-point calibration can be performed using the supplied standards. Calibration points can be modified when user prepared standards are used.
The HI 88713 turbidity bench meter has complete GLP (Good Laboratory Practice) functions that allow traceability of the calibration conditions.
The HI 88713 turbidity bench meter has a user-friendly interface with an easy to understand, graphic LCD. Comprehensive contextual help is available at a simple key press. Furthermore, a tutorial mode of operation guides the user step by step through the analysis process.
Up to 200 measurements can be stored in internal memory. Data can be transferred to a PC via optional HI 920013 USB cable and HI 92000 Windows® compatible software.
Order Information: HI 88713-02 (230V) is supplied with sample cuvettes and caps (6), calibration cuvettes, silicone oil, tissue for wiping cuvettes, power adapter and instruction manual.
Specification :
Range FNU Mode 0.00 to 9.99; 10.0 to 99.9; 100 to 1000 FNU
FAU Mode 10.0 to 99.9; 100 to 4000 FAU
NTU Ratio Mode 0.00 to 9.99; 10.0 to 99.9; 100 to 4000 NTU 0.00 to 9.99; 10.0 to 99.9; 100 to 980 EBC
NTU Non-Ratio Mode 0.00 to 9.99; 10.0 to 99.9; 100 to 1000 NTU 0.00 to 9.99; 10.0 to 99.9; 100 to 245 EBC
Resolution FNU Mode 0.01; 0.1; 1 FNU
FAU Mode 0.1; 1 FAU
NTU Ratio Mode 0.01; 0.1; 1 NTU / 0.01; 0.1; 1 EBC
NTU Non-Ratio Mode 0.01; 0.1; 1 NTU / 0.01; 0.1; 1 EBC
Accuracy @25°C FNU Mode ±2% of reading plus stray light
FAU Mode ±10% of reading
NTU Ratio Mode ±2% of reading plus stray light / ±5% of reading above 1000 NTU
NTU Non-Ratio Mode ±2% of reading plus stray light
Range Selection automatic
Repeatability ±1% of reading or stray light, whichever is greater
Stray Light < 0.1 NTU (0.05 EBC)
Light Detector silicon photocell
Light Source IR LED
Method ISO 7027 Method
Measuring Mode normal, average, continuous.
Turbidity Standards <0.1, 15, 100, 750 FNU and 2000 NTU
Calibration two, three, four or five-point calibration
Log Memory 200 records
PC Connectivity USB
Environment 0°C (32°F) to 50°C (122°F); max 95% RH non-condensing
Power Supply 12 Vdc power input
Dimensions / Weight 230 x 200 x 145 mm (9 x 7.9 x 5.7”) / 2.5 Kg (88 oz.)
Marga setia
Alamat : Jalan H.Kelik No.20 RT.03/RW.08 Kelapa Dua
Kebon Jeruk Jakarta Barat
Marketing : Nandang Kurnia
Telp : 081384449443
WhatsApp : 081384449443
Telp/Fax : 021-22054159
Email : nandangmargasetia@gmail.com
Atau kunjungi website kami :
http://nandangtehnik.blogspot.com/
www.margasetia.com
www.margasetiasurvey.com
Alamat : Jalan H.Kelik No.20 RT.03/RW.08 Kelapa Dua
Kebon Jeruk Jakarta Barat
Marketing : Nandang Kurnia
Telp : 081384449443
WhatsApp : 081384449443
Telp/Fax : 021-22054159
Email : nandangmargasetia@gmail.com
Atau kunjungi website kami :
http://nandangtehnik.blogspot.com/
www.margasetia.com
www.margasetiasurvey.com
Posting Komentar